-
Diagnosis of feline filariasis assisted by a novel semi-automated microfluidic device in combination with high resolution melting real-time PCR
- Back
Metadata
Document Title
Diagnosis of feline filariasis assisted by a novel semi-automated microfluidic device in combination with high resolution melting real-time PCR
Author
Phuakrod A, Sripumkhai W, Jeamsaksiri W, Pattamang P, Juntasaro E, Thienthong T, Foongladda S, Brindley PJ, Wongkamchai S
Name from Authors Collection
Scopus Author ID
35488706300
Affiliations
Mahidol University; National Science & Technology Development Agency - Thailand; National Electronics & Computer Technology Center (NECTEC); King Mongkuts University of Technology North Bangkok; George Washington University; George Washington University; Mahidol University
Type
Article
Source Title
PARASITES & VECTORS
Year
2019
Volume
12
Open Access
Green Published, gold
Publisher
BMC
DOI
10.1186/s13071-019-3421-z
Format
Abstract
Background: The diagnosis of filariasis traditionally relies on the detection of circulating microfilariae (mf) using Giemsa-stained thick blood smears. This approach has several limitations. We developed a semi-automated microfluidic device to improve and simplify the detection of filarial nematodes. Methods The efficiency and repeatability of the microfluidic device was evaluated. Human EDTA blood samples were 'spiked' with B. malayi mf at high, moderate, and low levels, and subsequently tested 10 times. The device was also used for a field survey of feline filariasis in 383 domesticated cats in an area of Narathiwat Province, Thailand, the endemic area of Brugia malayi infection. Results In the control blood arbitrarily spiked with mf, the high level, moderate level and low level mf-positive controls yielded coefficient variation (CV) values of 4.44, 4.16 and 4.66%, respectively, at the optimized flow rate of 6 mu l/min. During the field survey of feline filariasis in Narathiwat Province, the device detected mf in the blood of 34 of 383 cats (8.9%) whereas mf were detected in 28 (7.3%) cats using the blood smear test. Genomic DNA was extracted from mf trapped in the device after which high-resolution melting (HRM) real-time PCR assay was carried out, which enabled the simultaneous diagnosis of filarial species. Among the 34 mf-positive samples, 12 were identified as B. malayi, 15 as Dirofilaria immitis and 7 as broken vertical bar D. repens. Conclusions We developed a semi-automated microfluidic device to detect mf of filarial parasites that could be used to diagnose lymphatic filariasis in human populations. This novel device facilitates rapid, higher-throughput detection and identification of infection with filariae in blood samples.
Industrial Classification
Knowledge Taxonomy Level 1
Knowledge Taxonomy Level 2
Knowledge Taxonomy Level 3
Funding Sponsor
Faculty of Medicine Siriraj Hospital, Mahidol University [RO15936006]; National Science and Technology Development Agency, Ministry of Science and Technology, Thailand [P1551260]
License
CC-BY
Rights
Authors
Publication Source
WOS